Specifications


Data sheet

 

Title

ISOCELL - cellulose insulation fibre

fire protection

< 10% mineral flame retardant

technical approval

ETZ ETA – 06/0076

quality control external

OiB

blow - in density according to technical approval


loose

28 - 40 kg/ m³

condensed in wall, roof or ceiling area

38 - 65 kg/ m³

thermal conductivity λ D (declared value) machine processed

0,039 W/ mK

reaction to fire

100 mm / B – s2, d0


40 mm / E

water vapour diffusion sesistance factor

µ = 1

airflow resistance

bei 30 kg/ m³ r = 5,3 kPa.s/ m²


bei 50 kg/m³ r = 25,1 kPa.s/ m²

normal degree of humidity

max. 12 %

water absorbtion at 30 kg/ m³

WP = 15,20 kg/ m²

at 65 kg/ m³

WP = 38,95 kg/ m²

nominal thickness loose up to 25cm

10 % Überhöhung

loose over 25cm

15 % Überhöhung

settlement loose 28 kg/ m³

max. 8 %

settlement condensed 38 kg/ m³

0 %

quality control producer


density

1 x wöchentlich

settlement

1 x wöchentlich

water absorbtion

1 x wöchentlich

reaction to fire

1 x wöchentlich

spec. thermal capacity

2,11 KJ / kg K

primary energy from nonrenewable resources PEI ne MJ/kg

7,5 MJ

primary energy from renewable resources Pei e MJ/kg

1,1 MJ

greenhouse gas emissions/ GWP

-0,8 kg CO2 eq/kg

influance on atmospheric acidity/ AP

3,1 g SO2 eq

toxicology

no medical risk (certificate existant), during work, the use of a dust mask is required

disposal

the material can be restored to the producer, assumed it is not contaminated

disposal clue

EWC: 17 06 04, 17 09 04, 20 03 01
Burning in a refuse incineration plant as mono-waste or together with other community refuse is permitted.