Title | ISOCELL - cellulose insulation fibre |
fire protection | < 10% mineral flame retardant |
technical approval | ETZ ETA – 06/0076 |
quality control external | OiB |
blow - in density according to technical approval | |
loose | 28 - 40 kg/ m³ |
condensed in wall, roof or ceiling area | 38 - 65 kg/ m³ |
thermal conductivity λ D (declared value) machine processed | 0,039 W/ mK |
reaction to fire | 100 mm / B – s2, d0 |
| 40 mm / E |
water vapour diffusion sesistance factor | µ = 1 |
airflow resistance | bei 30 kg/ m³ r = 5,3 kPa.s/ m² |
| bei 50 kg/m³ r = 25,1 kPa.s/ m² |
normal degree of humidity | max. 12 % |
water absorbtion at 30 kg/ m³ | WP = 15,20 kg/ m² |
at 65 kg/ m³ | WP = 38,95 kg/ m² |
nominal thickness loose up to 25cm | 10 % Überhöhung |
loose over 25cm | 15 % Überhöhung |
settlement loose 28 kg/ m³ | max. 8 % |
settlement condensed 38 kg/ m³ | 0 % |
quality control producer | |
density | 1 x wöchentlich |
settlement | 1 x wöchentlich |
water absorbtion | 1 x wöchentlich |
reaction to fire | 1 x wöchentlich |
spec. thermal capacity | 2,11 KJ / kg K |
primary energy from nonrenewable resources PEI ne MJ/kg | 7,5 MJ |
primary energy from renewable resources Pei e MJ/kg | 1,1 MJ |
greenhouse gas emissions/ GWP | -0,8 kg CO2 eq/kg |
influance on atmospheric acidity/ AP | 3,1 g SO2 eq |
toxicology | no medical risk (certificate existant), during work, the use of a dust mask is required |
disposal | the material can be restored to the producer, assumed it is not contaminated |
disposal clue | EWC: 17 06 04, 17 09 04, 20 03 01 Burning in a refuse incineration plant as mono-waste or together with other community refuse is permitted. |